Infutest 2000 RSM

infutest_series_e

Infutest 2000 RSM

Remote Sensor Module

  • Quickly and easily add two additional channels to Infutest 2000
  • Automatically assigns Channels C and D
  • No software to upgrade
  • No configuration – Simply plug and go

  • Overview
  • Features
  • Specifications
  • Accessories
  • The flexibility you need
    Use Infutest 2000 RSM with your Infutest 2000 when you need it and store it when you don't. Simply plug in the Infutest 2000 RSM to add two channels to Infutest 2000 E Series. Infutest 2000 RSM gives you more options.
    • Quickly and easily add two channels to Infutest 2000
    • Automatically assigns Channels C and D
    • No software to upgrade
    • No configuration – Simply plug and go
    • All the benefits, accuracy and dependability of your Infutest 2000 in an easy-to-use accessory
  • (Infutest 2000 RSM – Performance Specifications)

    Single Rate Test (Continuous Flow Conditions)
    Flow Measurement
    Nominal range:0.1 - 1200 ml/hr
    Max. flow measurable and displayed:1700 ml/hr
    Min. flow measurable and displayed:0.04 ml/hr
    Max. display resolution:0.001 ml/hr
    Measuring time:10 min. at 0.1 ml/hr / 20 sec. max. above 6 ml/hr
    Accuracy: Average flow:+/- 1%, 0.1- 1200 ml/hr
    Ranges:LOW - 0.1 to 170 ml/h
    HIGH - 170 to 1200 ml/h
    Range selection:Automatic
    Internal nominal effective collection volume:LOW range: 0.014 ml
    HIGH range: 1.1 ml
    Volume Measurement
    Range:0 - 9999 ml, Max. display resolution: 0.001 ml
    Accuracy: +/- 1%
    Back Pressure Measurement
    Range:0 - 300 mmHg, Zero offset error:+/- 5 mmHg,
    Display resolution:1 mmHg, Accuracy:+/- 1% FS, +/- zero offset error
    Elapsed Time Measurement
    Range:0 - 100 hours, Display format:hh:mm:ss, Accuracy: +0/-1second
     
    Pulsatile Flow Conditions
    Flow Measurement
    Nominal range:5 - 999 ml/hr
    Max. flow measurable and displayed:1700 ml/hr
    Min. flow measurable and displayed:2.75 ml/hr
    Max. display resolution:0.001 ml/hr
    Measuring time:14 min. at 5 ml/hr / 20 sec. max. above 200 ml/hr
    Accuracy:Average flow +/- 1%
    Range:HIGH range only (internally selected)
    Internal nominal effective collection volume:1.1 ml
    Volume Measurement
    Range: 0 - 9999 ml, Max. display resolution: 0.001 ml,
    Accuracy: +/- 1%
     
    Dual Rate Test (Continuous Flow Conditions ONLY)
    Flow Measurement
    Nominal range:0.1 - 170 ml/hr
    Max. flow measurable and displayed:200 ml/hr
    Min. flow measurable and displayed:0.04 ml/hr
    Max. display resolution:0.001 ml/hr
    Measuring time:10 min. at 0.1 ml/hr / 20 sec. max.
    above 6 ml/hr
    Accuracy:Average flow: +/- 1%
    Ranges:LOW range only
    Delivery period determination:Automatic
    Internal nominal effective collection volume:0.014 ml
     
    PCA Pump Test (Continuous Flow Conditions ONLY)
    Flow Measurement, Bolus Delivery period
    Nominal range:0.1 - 170 ml/hr
    Max. flow measurable and displayed:200 ml/hr
    Min. flow measurable and displayed:0.04 ml/hr
    Max. display resolution:0.001 ml/hr
    Measuring time:10 min. at 0.1 ml/hr / 20 sec. max. above 6 ml/hr
    Accuracy:Average flow: +/- 1%
    Ranges:LOW range only
    Lockout detection:Automatic
    Internal nominal effective collection volume:0.014 ml
    Occlusion Pressure Test
    Display Units:mmHg, psi / Display resolution:1 mmHg(0.1 psi)
    Range:0 - 2586 mmHg(0 - 50 psi)
    Measuring time:2 seconds
    Zero offset error:+/- 5 mmHg (0.1 psi) Accuracy:+/- 1% +/- zero offset error
    Lockout Time Measurement
    Range:0 - 100 minutes, Display format:mm:ss,
    Accuracy:+/- 2 seconds
    Nurse Call Detection
    Nurse Call signal from pump sampled once per second.
    Nurse Call signal can be produced by any of: relay contacts, open collector output, TTL output, RS-232 level, or 20 mA current loop.
    Memory Type:
    NVRAM (battery-backed)
    Capacity:
    2 channel:900 flow and 700 pressure measurements per channel
    4 channel:450 flow and 350 pressure measurements per channel
    Interface
    User Interface:40-character by 8-line backlit LCD, 4 front
    panel soft-keys,
    Internal beeper:LCD contrast control
    Fluid interface:
    Inputs A & B:Delrin twistlock, self-sealing / Common output A & B: Delrin twistlock
    PCA Pump Trigger Outputs:
    MechanicalOne 1/4" female stereo phono jack per channel
    ElectricalRelay contacts rated at 120 VAC, 1 A; normally open
    and normally closed contacts available.
    Nurse Call Inputs:
    Mechanical- One 1/4" female stereo phono jack per channel
    Electrical- 50K-ohm differential input impedance.
    Parallel Port
    Centronix standard printer interface, DB-25F
    Printer Driver
    Epson MX/FX Series, 80 cps ,80 columns and 66 lines / page
    Serial Port:
    Mechanical - RS-232 / DB-25M
    Electrical - RS-232C; bidirectional; CTS handshaking;
    9600 baud, 8-None-1
    Power Supply:
    120 VAC 60 Hz @ 12 W (230/240 VAC 50 Hz
    Europe/UK)
    Environment:
    15°C to 40°C, 10% to 90% RH, Indoor Use Only, Category II;
    Dimensions:
    12" W x 12" D x 6" H (30.5 cm W x 30.5 cm D x 15.2 cm H)
    Weight:
    10 lbs. (4.5 kg)
     
    All specifications subject to change without notice.
  • Infutest RSM Accessories

    3000-004Power Cord, UK
    3000-005Power Cord, Aus / CN
    3000-006Power Cord, EU
    3000-471Power Cord, NA
    3000-472Power Supply, SPS
    3140-399Adaptor, USB To Serial DB9M
    7006-006Syringe, 60 cc, Luer Lock Tip
    7006-050Accessory Bag, 8.5" x 6" x 2.75" (Large)
    7006-051Accessory Bag, 8.5" x 2.9" x 2.6" (Small)
    7006-052Accessory Bag, 7" x 5" x 3" (Medium)
    7006-054Soft Case, Medium Multi-Product, 17" x 14" x 7"
    7006-055Soft Case, Large Multi-Product, 17" x 14" x 11"
    7100-279Cable Assembly, AUX-1
    7300-005Assy, 2 CH IFT Input Output Tubing