vPad-O2

Slide background
Slide background

vPad-O2

SpO2 Tester

vPad-O2 is the next generation SpO2 tester. Built on the vPad platform, vPad-O2 is user programmable so new sensors can easily be added in the field without needing to send the unit back to a service centre for upgrading. Being part of the vPad-A1 family, vPad-O2 can be upgraded to include a Multi-Parameter Patient Simulator and / or a NIBP Simulator.

  • Features
  • Specifications
  • Accessories
    • Compatible with all major industry manufacturers
    • Field editable R Curves allows for easy set up of new oximeters
    • Unlimited preset patient simulations
    • Five automated test sequences for determining oximeter alarm response time
    • Four preset signal artifact simulations
    • Easy to navigate
    • Control via Bluetooth or USB
    • Auto Settings
    • Auto Sequences
    • Test reports
    • Field upgradeable
  • vPad-O2™ Performance Specifications

    Saturation (SpO₂)
    Range: 30% to 100%
    Increments: 1%
    Presets: 6, user definable
    Range of adjustment and presets may vary according to pulse oximeter
    specifications
    SpO₂ Accuracy
    Saturation within DUT specified range: ±1 count + specified accuracy of the DUT
    Heart Rate
    Range: 20 to 300 BPM
    Increments: 1 BPM
    Presets: 6, user definable
    Accuracy: ± 0.25 BPM (sync mode); otherwise, ±1 BPM
    Pulse Amplitude
    Range: 0 to 100%
    Increments: 1% steps.
    Presets: 6, user definable
    Accuracy: ± 1%
    Signal Artifact
    Four preset simulations:
    • Movement
    • Tapping (Spike artifact)
    • Shivering (Tremor artifact)
    • Shake Table (2.5Hz Sinewave)
    Auto Presets:
    Unlimited preset patient simulations

    Default Auto Presets:
    • Normal Adult
    • Hypoxia
    • Movement Artifact
    • Tachycardia
    • Bardycardia
    • Neonate
    • Low Perfusion
    • No perfusion
    • Tremor (Shivering Artifact)

    Alarm Tests:
    Automated test sequences for determining oximeter alarm response time to:
    • Low Saturation
    • Low Heart Rate
    • High Heart Rate
    • Low Perfusion
    • Signal Artifact
    Five defaults, plus unlimited programmable alarm sequences
    Communication / User Interface
    via vPad-A1 Base Unit: Android 5" tablet:
    • Touchscreen User Interface
    • Wired (USB) or Bluetooth mode
    • WiFi
    • 16 GB memory
    Dual XBUS for Datrend test automation
    Power Supply
    via vPad-A1 Base Unit:
    • External AC adapter
    • Internal rechargeable Li-Ion batteries (for 10 hrs of simulation with full charge)
    Dimensions
    98mm x 208mm x 30mm (3.85” x 8.2” x 1.18”) A1 Base
    90mm x 160mm x 24mm (3.54” x 6.3” x 0.95”) SpO₂ Probe
    Weight
    440g (0.96lb) A1 base
    122g (0.27lb) SpO₂ Probe
    Environment
    15°C to 40°C, 10% to 90% RH, Indoor Use Only,
    Category II
  • vPad-O2 Standard Accessories Accessories

    7500-505vPad-A1 Accessory Kit, NA
    7500-506vPad-A1 Accessory Kit, Europe
    7500-507vPad-A1 Accessory Kit, UK/Malaysia
    7500-508vPad-A1 Accessory Kit, AU/CN


    For more information, view the accessories list page

vPad-O2
Product Sheet
vPad-O2
Support
Find Out More
Have A Dealer Contact Me
*
*
*
*

captcha